RE-2Y(St)H-PIMF&RE-2X(St)H-PIMF
RE-2Y(St)H-PIMF&RE-2X(St)H-PIMF

RE-2Y(St)H-PIMF&RE-2X(St)H-PIMF

Über dieses Produkt

WebsiteBesuchen Sie die Produktseite
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)H-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, Note: Other core configurations manufactured upon request Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
Ähnliche Produkte
1/15
RE-2Y(St)H-PIMF & RE-2X(St)H-PIMF
RE-2Y(St)H-PIMF & RE-2X(St)H-PIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H-PIM...
DE-72175 Dornhan
RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF
RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREE...
DE-72175 Dornhan
RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF
RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCR...
DE-72175 Dornhan
RE-2G(St)H-CI-PIMF  FE180
RE-2G(St)H-CI-PIMF FE180
HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHED Th...
DE-72175 Dornhan
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATH...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H MP
RE-2Y(St)H & RE-2X(St)H MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MUL...
DE-72175 Dornhan
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)...
DE-72175 Dornhan
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED...
DE-72175 Dornhan
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)...
DE-72175 Dornhan
RE-2Y(St)YQY-fl-PIMF
RE-2Y(St)YQY-fl-PIMF
INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used ...
DE-72175 Dornhan
RE-2G(St)HSWAH-CI-TIMF  FE180
RE-2G(St)HSWAH-CI-TIMF FE180
HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-TRIPLE, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR ...
DE-72175 Dornhan
RE-Y(St)Y-fl-PIMF & RE-Yw(St)Yw-fl-PIMF
RE-Y(St)Y-fl-PIMF & RE-Yw(St)Yw-fl-PIMF
INSTRUMENTATION CABLES, EN 50288-7MULTİ-PAIR, PVC INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of...
DE-72175 Dornhan
SIMH-FR/PF FE 180
SIMH-FR/PF FE 180
HIGH TEMPERATURE, TWISTED PAIR RESISTANT TO FIRE SILICONE CABLES These twisted pairs (pair form) cables fields of use as a control and power supply c...
DE-72175 Dornhan
RE-2Y(St)Y-fl-TIMF
RE-2Y(St)Y-fl-TIMF
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED These cables are used...
DE-72175 Dornhan
RE-Y(St)Y-fl-MP
RE-Y(St)Y-fl-MP
INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmis...
DE-72175 Dornhan
Trend-Produkte
1/15
Markisen
Markisen
Markisen-Droste Sonnenschutzsysteme GmbH
DE-22393 Hamburg
Mehradrige Mantelleitungen & Kabelbäume
Mehradrige Mantelleitungen & Kabelbäume
Wetzel Industrieelektronik e.K.
DE-75378 Bad Liebenzell
Reparatur von Rasenmähern
Reparatur von Rasenmähern
Motorgeräte Müller
DE-08115 Lichtentanne
Holz-Fensterläden
Holz-Fensterläden
Klappladen-Online, Jürgen Matt, Dipl. Ing. (FH)
DE-77948 Friesenheim
Ankauf KFZ Kompletträder Reifen Räder Felgen
Ankauf KFZ Kompletträder Reifen Räder Felgen
Lagerclean GmbH
DE-33129 Delbrück
Kfz-Hebebühne STARLIFT
Kfz-Hebebühne STARLIFT
ESTET Stahl- und Behälterbau GmbH
AT-8770 St. Michael in Obersteiermark
ANHÄNGER FÜR DEN PROFESSIONELLEN EINSATZ
ANHÄNGER FÜR DEN PROFESSIONELLEN EINSATZ
Trebbiner Fahrzeugfabrik GmbH
DE-14959 Trebbin
Federholzleisten & Schichtholzleisten
Federholzleisten & Schichtholzleisten
Wemaflex GmbH Holzwerkstoffe
DE-33034 Brakel
Traktoren
Traktoren
WEMATIK GmbH
DE-48531 Nordhorn
Altschuhe, Gebrauchte Schuhe
Altschuhe, Gebrauchte Schuhe
SimayTex Textilrecycling
DE-89331 Burgau
Ankauf von gebrauchten Schuhen
Ankauf von gebrauchten Schuhen
VERSERO GmbH
DE-13127 Berlin
Hanf Samen
Hanf Samen
Less Organix Inh. Christoph Lesser
DE-97437 Haßfurt
HHC/THCP/CBG9 Großhandel
HHC/THCP/CBG9 Großhandel
Andreas Shimf
DE-21031 Hamburg
Zweiachs-Bauwagen
Zweiachs-Bauwagen
WEHA FAHRZEUG- & CONTAINERBAU GMBH & CO. KG
DE-78234 Engen