RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF
RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

Über dieses Produkt

WebsiteBesuchen Sie die Produktseite
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Blackk Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
Ähnliche Produkte
1/15
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED...
DE-72175 Dornhan
RE-2Y(St)YSWAY-fl-PIMF & RE-2X(St)YSWAY-fl-PIMF
RE-2Y(St)YSWAY-fl-PIMF & RE-2X(St)YSWAY-fl-PIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YS...
DE-72175 Dornhan
RE-Y(St)YSWAY-PIMF
RE-Y(St)YSWAY-PIMF
INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 2MULTİ-PAİR, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED PVC SHEATHED These cables are used...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H-MP
RE-2Y(St)H & RE-2X(St)H-MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MUL...
DE-72175 Dornhan
RE-2YCYSWAY-fl-PIMF
RE-2YCYSWAY-fl-PIMF
INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transm...
DE-72175 Dornhan
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)...
DE-72175 Dornhan
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATH...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H MP
RE-2Y(St)H & RE-2X(St)H MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MUL...
DE-72175 Dornhan
RE-2Y(St)H-PIMF&RE-2X(St)H-PIMF
RE-2Y(St)H-PIMF&RE-2X(St)H-PIMF
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)H-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHE...
DE-72175 Dornhan
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATH...
DE-72175 Dornhan
RE-2Y(St)Y-fl-MP
RE-2Y(St)Y-fl-MP
INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-PAİR, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmiss...
DE-72175 Dornhan
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZ...
DE-72175 Dornhan
SIMH-FR/PF FE 180
SIMH-FR/PF FE 180
HIGH TEMPERATURE, TWISTED PAIR RESISTANT TO FIRE SILICONE CABLES These twisted pairs (pair form) cables fields of use as a control and power supply c...
DE-72175 Dornhan
RE-2Y(St)Y-fl-PIMF & RE-2X(St)Y-fl-PIMF
RE-2Y(St)Y-fl-PIMF & RE-2X(St)Y-fl-PIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl-PIMF,MULTİ-PAİR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl-PIMF,MULTI-...
DE-72175 Dornhan
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)...
DE-72175 Dornhan
Trend-Produkte
1/15
goupil-g4-elektrotransporter
goupil-g4-elektrotransporter
Peter Krause GmbH
DE-88682 Salem
ANHÄNGER FÜR DEN PROFESSIONELLEN EINSATZ
ANHÄNGER FÜR DEN PROFESSIONELLEN EINSATZ
Trebbiner Fahrzeugfabrik GmbH
DE-14959 Trebbin
RASANT zweiachsig
RASANT zweiachsig
HBU GmbH
DE-19230 Bobzin
Ankauf von gebrauchten Schuhen
Ankauf von gebrauchten Schuhen
VERSERO GmbH
DE-13127 Berlin
SOLID
SOLID
HBU GmbH
DE-19230 Bobzin
Ankauf - Restposten und Sonderposten
Ankauf - Restposten und Sonderposten
Diesch Warenhandel
DE-88260 Argenbühl/Eglofstal
Parfüm
Parfüm
Parfum Trend
DE-63517 Rodenbach
GLS  Sendungsverfolgung
GLS Sendungsverfolgung
Meine Sendungsverfolgung
DE-18439 Stralsund
Brennholz Buche 33cm 1RM / 1,5SRM
Brennholz Buche 33cm 1RM / 1,5SRM
Ökobrennstoffe Förster GmbH
DE-08107 Kirchberg
Gebrauchte CNC-Fräsmaschinen
Gebrauchte CNC-Fräsmaschinen
SH-Werkzeugmaschinen Sascha Hof jun.
DE-86720 Nördlingen
Haro 4 SB Eiche Trend PV
Haro 4 SB Eiche Trend PV
ZEG Zentraleinkauf Holz+Kunststoff eG
DE-70806 Kornwestheim
SunPower®-Module
SunPower®-Module
activ solar Schweiz GmbH
CH-8617 Mönchaltorf
Mehradrige Mantelleitungen & Kabelbäume
Mehradrige Mantelleitungen & Kabelbäume
Wetzel Industrieelektronik e.K.
DE-75378 Bad Liebenzell